The 22mm Plastic Emergency Stop Push Button Switch is designed for controlled and maintained interruption of electrical circuits in elevator and lift control systems.
It adopts a standard 22mm mounting structure and a red mushroom head actuator to ensure high visibility and rapid identification on control panels. The self-locking (latching) mechanism maintains the stop state after actuation and requires manual reset before system restart.
This product is engineered for applications where predictable emergency shutdown, mechanical durability, and panel compatibility are essential.
High-contrast red mushroom head
Large surface area for fast activation
Easily distinguishable on complex control panels
Benefit: Reduces reaction time in emergency situations.
Maintains stop state after activation
Prevents unintended restart
Requires deliberate reset
Benefit: Ensures controlled system recovery.
Firm press resistance
Audible and physical “click” sensation
Clear confirmation of actuation
Benefit: Eliminates uncertainty during high-pressure moments.
High-strength plastic body
Resistant to corrosion and wear
Designed for long service life
Benefit: Reduces maintenance frequency and downtime.
Fits common control panel cutouts
Compatible with existing elevator designs
Easy retrofit capability
Benefit: Simplifies integration without redesign.
Usage | |||
AC—15 | DC—13 | ||
Rated operating voltage Ue V | Rated operating current Ie A | Rated operating voltage Ue V | Rated operating current Ie A |
220 | 0.75 | 125 | 0.22 |
120 | 1.5 | 24 | 1.0 |
The corresponding value of intermittent cycle working system (number of operating cycles per hour (operating frequency) and load factor (power-on duration): 1200 times /hour is 25%; 300 times /hour is 40%).
Maintains stop state after actuation
Requires manual reset before restart
Prevents automatic re-energization
The latching mechanism ensures system shutdown remains effective until intentional intervention occurs.
Red actuator for standardized emergency indication
Mushroom head increases surface contact area
Easily distinguishable from standard operation buttons
This configuration supports rapid identification under emergency conditions.
Stable internal contact structure
Designed for repeated actuation cycles
Reduced risk of unstable connection
The internal contact design ensures consistent circuit interruption when activated.
Standardized Panel Compatibility
22mm mounting hole requirement
Secure threaded fixing
Compact rear structure for panel depth management
The standardized mounting dimension allows integration into existing control panel layouts without structural modification.
Wiring Considerations
Compatible with common control circuit configurations
Suitable for emergency stop safety loop integration
Designed for stable terminal connection
Proper wiring should follow system safety design and electrical regulations.
Emergency stop switches must comply with general industrial safety design principles. This product supports those principles through:
Prominent red actuator
Maintained stop function
Manual reset requirement
Clear physical separation from operational buttons
It is intended for integration within structured safety circuits and control systems designed to interrupt power or signal flow under emergency conditions.
Each unit undergoes controlled production and inspection processes:
Incoming material verification
Mechanical endurance testing
Electrical continuity testing
Actuator alignment inspection
Final assembly quality check
These measures ensure consistent mechanical feel and stable electrical performance across production batches.


No. It uses a self-locking (latching) mechanism and must be manually reset after activation.
Yes. It is designed for standard 22mm panel mounting holes.
Yes. It is specifically designed for elevator and lift control panel applications.
The housing is made of industrial-grade plastic providing insulation and corrosion resistance.
Yes. It is suitable for any system requiring maintained emergency stop functionality, provided electrical compatibility is confirmed.